![]() Production Discontinued SEP/17 |

Model | RGX3600 | |||
GENERATOR | Type | Brushless, Single Phase Revolving Field, 2-Pole |
||
Voltage (V) | 50HZ/220V ,50HZ/240V 60HZ/110V・220V |
|||
Ac output (KVA) |
Max. | 50HZ | 3.0 | |
60HZ | 3.6 | |||
Rated | 50HZ | 2.4 | ||
60HZ | 2.9 | |||
Power factor | 1.0 | |||
ENGINE | Model | EX21 | ||
Type | Air-Cooled,4-Cycle | |||
Displacement (ml) | 211 | |||
Fuel | Automobile Gasoline | |||
Tank capacity (l) | 12.8 | |||
Continuous Operating Hours (h) |
50HZ | 9.5 | ||
60HZ | 8.4 | |||
Dimensions L x W x H | 605 x 450 x 500 | |||
Dry Weight(kg) | 54 |
Specifications are subject to change without notice.
High Performance is achieved by the powerful EX engine series with sophisticated OHC system
Quiet Operation
- Silent muffler achieve quiet operation.
Stable Output
- Brushless alternator and automatic voltage regulator (Condenser type) realize stable outputs.
Longer Operation
- 12.8L fuel tank realizes continuously longer operation.
Oil Sensor equipped as a standard
- Oil sensor automatically shut off the engine whenever oil level is too low.

STANDARD EQUIPMENT
- AC Circuit Breaker
- AC Voltmeter
- DC Output
- Oil Sensor
- 12.8L Large Fuel Tank
- Silent Muffler

High Performance is achieved by the powerful EX engine series with sophisticated OHC system
Quiet Operation
- Silent muffler achieve quiet operation.
Stable Output
- Brushless alternator and automatic voltage regulator (Condenser type) realize stable outputs.
Longer Operation
- 12.8L fuel tank realizes continuously longer operation.
Oil Sensor equipped as a standard
- Oil sensor automatically shut off the engine whenever oil level is too low.
EX engine series superior to engines in the same class
Extremely silent
- Soft tone quality
- EX engines are 2dBA quieter and softer in tone than other engines in the same class.
Extremely easy start
- No kick-back
Extremely easy maintenance
Extreme reliability and durability are achieved by:
- Heavy Duty Chain Driven OHC System
Environmentally friendly
- EX engines comply with EPA and CARB Emission Regulation in the USA.

STANDARD EQUIPMENT
- AC Circuit Breaker
- AC Voltmeter
- DC Output
- Oil Sensor
- 12.8L Large Fuel Tank
- Silent Muffler
OPTIONAL EQUIPMENT