Production Discontinued SEP/17


Model RGD2500S-Ⅱ
GENERATOR
Type Brushless, self-exciting, 2-poles, single phase
Voltage regulator Condenser type
Ac output Frequency 50Hz 60Hz
Rated voltage 110V,220V,240V
110V/220V
110V,120V,220V
110V/220V,120V/240V
Rated output 2000W 2200W
Maximum output 2300W 2500W
DC output(Option) 12V-8.3A(100W)
Power factor 1.0
Over current protector Fuseless circuit breaker
ENGINE Model DY23-2DS
Type Robin air-cooled, 4-stroke, diesel engine
Displacement 230cm3
Fuel Diesel light oil
Fuel tank capacity 11.5L
Continous operating hours
at rated output
14.0h 11.9h
Starting system Electric starter
Dimensions L x W x H 722 x 538 x 667mm
Dry Weight 106kg
Noise level(rated at 7m) 63.7dBA 64.6dBA
Specifications are subject to change without notice.


QUIET OPERATION
-Precisely synchronized fuel injection system and refined combustion chamber of the Robin air-cooled diesel engine generate less noise.The sturdy enclosure with sound insulating linings assures whisper quiet operation.

ECONOMICAL PERFORMANCE
-On top of well known diesel economy,the air-cooled Robin diesel engine features direct fuel injection and special design refinements for extra fuel economy.

OPERATOR CONVENIENCE
1) Condenser voltage regulationCondenser voltage regulation ensures stable voltage output under all working conditions.
2) One touch start
Easy and accurate start/stop are assured by operating one key only.
3) Front mounted control panel
- Simply designed control panel assures easy access and accurate operation.
- Both large sized Oil and Battery indicator lamps timely notify an operator of any unusual condition.
4) Long operation
Large fuel tank for continuous operation sufficient for a full day's work without refuelling.
5) Hour meter
Hour meter for monitoring accumulated operation time.

MINIMAL MAINTENANCE
1) Brushless alternator
Brushless alternator eliminates time consuming brush maintenacce.
2) Large door for maintenance
Large door gained by redesigning exterior and interior.
3) Automatic air bleeding mechanism
Automatic air bleeding mechanism ensures start after refuelling.
4) Protection for battery cuircuit
Protective electric circuits newly introduced prevent problems caused by incorrect electrical polarity.
5) Dust proof double element air cleaner
Double element air cleaner protects engine in dusty environment.

STANDARD EQUIPMENT
- Automatic air bleeding mechanism
- DC output
- AC/DC Circuit breakers
- Full-power switch on dual voltage
- Extra large fuel tank with fuel gauge

OPTIONAL EQUIPMENT
- Dust-proof cyclone air cleaner
- Battery charge warning lamp
- Low oil warning and automatic stop system
- Engine hour meter
- Electric Starter